Air Conditioning Basics: A/C 101
Recommended Performance Based Air Conditioning
Specifications
An air conditioning system shall be supplied that at
an ambient temperature of 95degrees Fahrenheit and at 50% humidity is
capable of reducing the temperature inside the vehicle 25 degrees F
within 30 minutes of listed situation. The installation of the said
system shall be performed by factory trained technicians in a manner
consistent with accepted industry standards. System will be evaluated
based upon the quality and performance of the components supplied,
ability to meet a pull down test, warranty period, installation
reputation, size, weight, durability, reliability, head pressure
analysis, electrical load test, and amount of engine RPM's required to
operate the system. Vendor shall submit all technical data with this bid
as requested below. In addition to these requirements the complete a/c
system installation shall be subject to a final ultrasonic leak
detection test. Other requirements:
- Only HFC -134A environmentally friendly
refrigerant shall be used
- The compressor/s used shall be the best available
for the bus specified and shall be warranted for 2 years minimum.
The compressor mounting bracket/s shall be of sufficient strength to
support the compressor and bed belt loads and yet insure that the
drive pulley (electric clutch assembly) remains in close alignment
with the engine drive pulley. Suitability of the compressor/s will
be judged based upon the results of the performance test and data
supplied by the bidder.
- A/c system shall be "Made in America."
- The interior evaporators (if used) shall be
fastened and supported to the roof bows as per industry standard
accepted practices.
- Evaporator drains shall do so below the floor
line. Drain lines shall be made of high quality material and shall
be concealed from the interior. (Except roof top models!)
- The Interior ABS Covers shall have No
sharp corners or edges.
- The Interior ABS Plastic Covers used shall
conform to FMVSS #302 guidelines.
- Refrigerant hoses shall be of a barrier design to
prevent permeation.
- Evaporator and condenser coils shall be advanced
rifled design or equal for maximum heat transfer
efficiency.
- Condensers shall be constructed of lightweight,
non-corrosive, aircraft aluminum or equal.
- All Wiring shall be color-coded and run through
jacketed harnesses (not split-loom type). Color-coded wiring and
piping diagrams shall be supplied with bid.
- All condenser/s shall include a sight glass with
"O" ring fitting.